banner
Home / Products / Siren AMP
Products
Factory Conventional Fire Detection Alarm Panel for Fire Security System

Factory Conventional Fire Detection Alarm Panel for Fire Security System

Package size per unit product 48.00cm * 42.00cm * 18.50cm Gross weight per unit product 10.000kg Factory Conventional Fi
Basic Info
Model NO. SR-P01-16
Type Fire Alarm Host
Function Networked
Usage Fire
Certification CE
Alarm Volume (within 1m) ≥80dB
Networking Mode Wire
Wiring Mode Sub-Line System
Color Red
Fire Panel Type Conventional
Zone Number 4 Zone, 8 Zone, 16 Zone Optional
Net Weight 11kg
Name Factory Conventional Fire Detection Alarm Panel F
Transport Package Carton
Specification 220VAC, 50 Hz.
Trademark SUMRING
Origin China
HS Code 8531901000
Production Capacity 5000 PCS/Month
Packaging & Delivery
Package size per unit product 48.00cm * 42.00cm * 18.50cm Gross weight per unit product 10.000kg
Product Description

Factory Conventional Fire detection Alarm Panel for security system

Product Description
SR-P01-4 4 zones conventional fire alarm control panelSR-P01-8 8 zones conventional fire alarm control panelSR-P01-16 16 zones conventional fire alarm control panel

Main features:
Four, Eight, Sixteen Zone Style B (Class B) Initiating Device Circuits (IDCs), All zones accepttwo-wire smoke detectors and any normally-open contact devices.Two Supervisory Input with DC12V output, ideal to connect security alarm devices.Three General Alarm, Trouble and Supervisory, Form A Relay Output.One, Two, Four Built-in Sound Output, Style Y (Class B) Notification Appliance (Signal) Circuits(NACs), NACs may be programmed: Silenceable or Non-Silenceable.3.0 amps of total system power. Resettable DC24V & Non-resettable DC24V Output.Zone Input Short Circuit can be set to "Alarm" or " Fault" mode.RS485 Communication Port (optional).Automatic/Manual mode can be programmed.Disable/Enable control per Zone (IDC) can be programmed.Disable/Enable Sound Output(NACs) can be programmed.

Technical Parameters

AC Power220VAC, 50 Hz.
BatterySealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge
Maximum battery charger capacity18AH battery
NOTETwo 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box
Total DC24V system power3.0 amps
Maximum current per NAC1.25 amps
Resettable four-wire smoke detector power output.yes
Non-resettable power output.yes
Integral Form-A Alarm, Trouble and Supervisory relays, rated at2.0 amps @ 30 VDC(resistive), 2.0 amps @ 30 VAC (resistive)

Product show:

Factory Conventional Fire Detection Alarm Panel for Fire Security System

 

Factory Conventional Fire Detection Alarm Panel for Fire Security System

This fire alarm control panel can Match any 2/4-wire smoke heat detector,strobe siren,fire bell,manual call point ect

smoke detector2 wire, 4 wire optiona, photoeletrci type
heat detector2 wire, 4 wire optional, rate of rise or fixed temeparture
strobe sirenwired type, with or without strobe
fire bellwired type, indoor or outdoor type
manual call pointresettable type or breaking glass type optional

Not only the alarm control panel we have, but also we offer all kinds of detectors you want, we are looking forward to your inquiry, thank you!

 

Factory Conventional Fire Detection Alarm Panel for Fire Security System


MORE INFO: https://cnsumring.en.made-in-china.com/